Why Hybrid solar air-conditioner can save electricity?
Here are the reasons:
Firstly, it absorbs solar energy to heat the inside medium by using a solar collector. Freon from the compressor goes through the copper coil inside the collector and undertakes a heat exchange. Freon exchange heat with the medium inside the solar collector then go through a cycle inside the system for cooling and heating.
Secondly, it adopts a highly efficient heat-exchange system. The use of the internal thread pipe, hydrophilic aluminum fin and the optimal heat exchange system reduce energy loss, improve the overall efficiency and effectively ensure the performance. Therefore, hybrid solar air conditioner is more convenient and energy-saving than regular air conditioner.
Comparing to Current Products
1. Conventional air conditioner consumes too much, users have to pay a heavy electricity bill.
2. Photovoltaic (PV) system costs a large amount of money to build up.
3. Thermally driven absorption cooling is also very costly, and its cooling capacity is not big enough.
Tips on electricity saving of air conditioners: According to China National Management Method of Energy Efficiency, EER refers to the proportion between cooling capacity and power input, which is the only data used to value the energy-saving of air conditioners. The bigger it is the electricity it saves. If two AC with the same power consumption, the one with bigger capacity is better on electricity saving.
Performance Characteristics
High Performance Japanese Brand Compressor
Durable and long-lived, smooth running. Low-loaded operation of the compressor to extend its duration.
Four-fold Heat Exchanger
As one of the main components of air conditioner, Chuanglan hybrid solar air conditioner adopts four-fold heat exchanger (take Supreme Silent as an example) heat exchanger effective area is increase by 20-40% than V-shape and flat heat exchangers, thus the cooling and heating effect are improved greatly.
High-quality Internal Thread Copper Pipe
Compared with normal copper pipe, the heat exchanging area of internal thread cooper pipe is significantly enlarged so does the exchange effect. Meanwhile, it can resist frosting and increase its starting ability at low temperature.
Hydrophilic aluminum foil to prevent the appearing of water bridge, thus to ensure the performance of heat exchange.
Model No. | TKF(R)-72NW | TKF(R)-100NW | TKF(R)-120NW | ||
Power Supply:220-240VAC, 1/3PH, 50Hz/60Hz | |||||
Performance | |||||
Capacity | Cooling | Btu/h | 24000 | 36000 | 41000 |
W | 7200 | 10000 | 12000 | ||
Heating | Btu/h | 27000+1700 | 40000+1700 | 46000+1700 | |
W | 7900+500 | 12000+500 | 14000+500 | ||
Noise | Indoor | dB(A) | ≤48 | ≤48 | ≤48 |
Outdoor | dB(A) | ≤58 | ≤58 | ≤60 | |
Air Circulation | m³/h | 1400 | 2400 | 2400 | |
Static Pressure | Mpa | 30 | 50 | 50 | |
Suitable Area | m² | 30~48 | 42~67 | 50~80 | |
EER | W/W | 3.82 | 3.87 | 3.96 | |
Btu/h/w | 13.03 | 13.2 | 13.51 | ||
Power Consumption | |||||
Power Input | Cooling | W | 1700~1900 | 2400~2640 | 2900~3150 |
Heating | W | 1700~1950+500 | 2470~2650+500 | 2900~3180+500 | |
Rated Current | Cooling | A | 7.73~8.64 | 10.91~11.95 | 13.18~14.32 |
Heating | A | 7.73~8.66+2.2 | 11.23~12.05+2.2 | 13.18~14.45+2.2 | |
Vacuum Tube | Diameter*Length*Pcs | 47mm*620mm*11 | 47mm*700mm*13 | 47mm*1200mm*13 | |
Dimensions | |||||
Indoor Unit | Net | mm | 1580*475*235 | 1940*475*235 | 1940*475*235 |
Outdoor Unit | Net | mm | 940*300*755 | 950*355*835 | 950*355*1255 |
Shipping | mm | 990*400*770 | 1140*460*910 | 1140*460*1340 | |
Water Tank | Shipping | mm | 980*400*370 | 1120*400*400 | 1120*400*400 |
Vacuum Tube | Shipping | mm | 1270*280*210 | ||
Weight | |||||
Indoor Unit | Net/Gross | kg | 28 | 38 | 38 |
Outdoor Unit | Net/Gross | kg | 55/58 | 73/76 | 95/100 |
Solar Collector | Net/Gross | kg | 16/17 | 18/21 | 23/26 |
REMARKS:
Aboved Red Numbers means the electrical heater is on.
Parameters in the form are messured in the rated working state acording to GB/T7725-2004. Changes may appear according to real working state.
Parameters may change due to the product improvement, please refer to the products nameplate.
Unit conversion
1Ton | (12,000 BTU) |
1.5 Ton
|
(18,000 BTU) |
2 Ton
|
(24,000 BTU) |
2.5 Ton
|
(30,000 BTU) |
3 Ton
|
(36,000 BTU) |
3.5 Ton
|
(42,000 BTU) |
4 Ton
|
(48,000 BTU) |
5 Ton
|
(60,000 BTU) |
1Ton=3024 kcal/h = 3.517KW
|
1Btu/h = 0.293W |